A 10 m reel tells you how much tape is in the pack. To decide whether it can run 10 m from one end, check the exact COB LED strip model’s supported feed length, voltage and wattage. If the proposed run exceeds that limit, plan shorter fed sections or another feed arrangement approved for the model.

Three lengths to put on the order
| Length | What it means | What to specify |
|---|---|---|
| Reel length | Metres of tape shipped on each reel. | Metres per reel and reel count for each SKU. |
| Cut length | Usable piece length between marked cut points. | Finished lengths and tolerances, based on the selected cut pitch. |
| Powered run | Tape length served by the proposed feed arrangement. | Longest run, feed positions and the model’s limit for that wiring. |

Choose 1 m, 3 m, 5 m, 10 m or 20 m by the cut list
Compare short lengths for samples or replacement pieces, 5 m and 10 m reels for stock or site cutting, and 20 m reels for jobs that consume multiple pieces from the same roll. Confirm which lengths are available for the exact model, voltage and finish. For labelled units, see the wholesale packaging guide.

When to ask for pre-cut lengths
For repeat fixtures, send the finished length, piece count and required lead end. Ask the supplier to confirm the closest cut mark, length tolerance, lead length and any end seal before quoting. Use a separate purchase-order line for each version. Work Out How Many Reels to Order.

Map the installed runs and feed points
Need LED strips for your order?
Tell us the strip type or model, key specifications, quantity in metres and destination country. We can share actual product photos, check available CE/RoHS documents for the selected model, and suggest compatible power supplies or controllers.
Mark the start, end and driver location for each light line. Record the longest cable route and which runs need independent control. Then compare the longest distance along the strip from a feed with the limit for that model and wiring.
Compare voltage using the exact model
At equal wattage, 24 V draws half the current of 12 V. For example, a 100 W load draws about 4.2 A at 24 V versus 8.3 A at 12 V. That can reduce voltage drop in the supply cable, while the strip’s own circuit still determines its usable feed length. Review the 24 V COB range or, for a separately designed mains-voltage system, the 120 V COB guide.
Select a feed arrangement
- Single-end. Use when the model is rated for the complete run from one end.
- Centre feed. Feed two shorter branches in parallel from an accessible midpoint, with the driver sized for the combined load.
- Dual-end. Where the strip and system documentation allow it, supply both ends from the same appropriately rated circuit. Keep separate driver outputs isolated unless the manufacturer explicitly supports paralleling.
- Zoned. Divide long lines into separately fed sections where driver access, service or control requires it.
Use the COB connector and power supply guide to check connections and drivers.

Compare model-specific cut lengths
The catalogue lists a 25 mm cut interval for the 12 V version of its 320 LEDs/m, 8 mm COB strip, and about 45.45 mm for the 528 LEDs/m, 10 mm, 24 V strip. Check the exact SKU’s datasheet and sample marks before locking finished dimensions. For damp locations, specify the protection required for the strip, leads and finished joints. IEC IP rating system
Examples from commercial layouts
In an office ceiling, plan feed access and where joints can sit under the diffuser. In a hotel corridor, align separately serviceable sections with architectural breaks. Office linear ceiling case · Long corridor case
Check the far end and the joins
At full output, compare brightness at the feed and the far end after warm-up. If the far end is dimmer, check the voltage at the strip, the supply cable and the connections before adding more tape.
Compare adjacent reels before installation
Check samples side by side at the same output and with the intended diffuser. Agree on colour tolerance, batch marking and replacement stock where continuous lines must match. CIE colour reference · U.S. Department of Energy LED lighting guide
Allow for cut marks, leads and spares
Account for the physical length of connectors and end seals, and decide which offcuts can serve as spares. A total metre count alone can leave you short of full-length pieces.

COB LED strip length FAQ
Is one 10 m reel better than two 5 m reels?
Compare how many full pieces each option yields, the number of acceptable joins and the remaining usable offcuts. Size the feeds separately.
Can I use a 20 m COB LED strip?
Confirm whether the model is offered on a 20 m reel, then check how many powered sections the installation needs. Use 20 m on one feed only where the specific strip and arrangement support it.

Request a reel and cut-length quote
Send the strip model or voltage, colour and width, finished lengths and quantities, longest powered run, proposed feeds, metres per reel and delivery country.
Send your run list to Senfey →